DC Balanced Reactor
    Variable Frequency Drive
    DC Flat Wave Reactor
    Input Reactor
    Output Reactor
    Energy Feedback Reactor
    Reactor of PMSM
    Rotor Inverter BOOST Reactor
    Dv/dt Filter
    Sine Wave Filter
    Passive Harmonic Filter
    LCL Filter
    EMC Filter
    Power Quality
    SVG Reactor
    APF Reactor
    Three Phase Series Detuning Reactor
    Three Phase Series Tuned Reactor
    Single-phase series detuning reactor
    New Energy
    Wind Power Filter Reactor
    Photovoltaic Filter Reactor
    Photovoltaic Isolation Transformer
    Transformer
    Rectifier Transformer
    Power Frequency Transformer
    Energy Consumption Braking
    Braking Unit
    Wirewound Resistor
    Aluminum-enclosure Resistor
    Braking Resistance Box
    Braking Resistance Cabinet
    Electric Vehicle
    BOOST Reactor For EV
    PFC Reactor for Charger
    High Frequency Reactor
    High Frequency Transformer

    Recommend

    Output Reactor

    Time:2024-01-19     Visits:4


    Circuitry application:

             In Inverter with asynchronous motor system, output reactor is installed at output side of the Inverter, inhibits the higher harmonic current caused by the switching frequency ripple current, reduces the dv/dt instantaneous voltage caused by traveling wave reflection in long cable transmission, so as to reduce the eddy-current losses and the noise of the  motor, and to protect the motor insulation.

    201807251829034963.png

    Performance features:


        Rated voltage

      3-AC400V/AC690V/AC1140V,50HZ

        Insulation grade

      F/H

        Noise

      ≤70 d B

        Electric strength

      AC3000V/AC4200V   50Hz  5s  leakage current≤5m A

        Ambient temperature

      -25℃~55℃/(75℃,explosion-proof)

        Operative norm

      GB10229-88 reactor、IEC289:1987 reactor、JB9644-1999 reactor for transmission semiconductor    



    Solutions for the input side of the Inverter:

    201807251829226682.png

    Dimensions and technical parameter:

    201807251829423557.png



    Technical parameter of output reactor(UD=1%


    System voltage: 3-AC400V,50HZ, Insulation level: F

    Specifications and   models

    Figure  No.

    Carrier frequency(KHZ

    Power of frequency converter (kW)

    Rated current(A)

    Inductance   (mH)

    Weight   (KG)

    Dimensions(mm)

    W

    D

    H

    W0

    D0

    A*B

    SOCL-0005-EISC-140B

    A

    5

    2.2

    5

    1.4

    1.5

    93

    69

    110

    40

    48

    7*11

    SOCL-0010-EISC-700C

    5

    3.7

    10

    0.7

    2.6

    115

    73

    125

    50

    53

    7*11

    SOCL-0013-EISC-540C

    5

    5.5

    13

    0.54

    2.8

    115

    73

    125

    50

    53

    7*11

    SOCL-0016-EISC-438C

    5

    7.5

    16

    0.438

    2.9

    115

    73

    125

    50

    53

    7*11

    SOCL-0025-EISC-280C

    B

    4

    11

    25

    0.28

    5.3

    150

    95

    160

    60

    67

    7*11

    SOCL-0030-EISC-233C

    4

    15

    30

    0.233

    5.6

    150

    95

    160

    60

    67

    7*11

    SOCL-0040-EISA-175C

    C

    4

    18.5

    40

    0.175

    5.7

    180

    110

    160

    80

    67

    7*11

    SOCL-0045-EISA-155C

    4

    22

    45

    0.155

    5.8

    180

    110

    160

    80

    67

    7*11

    SOCL-0060-EISA-117C

    3

    30

    60

    0.117

    8.4

    180

    130

    160

    80

    87

    7*11

    SOCL-0075-EISA-935D

    3

    37

    75

    0.0935

    8.7

    180

    130

    160

    80

    87

    7*11

    SOCL-0090-EISA-785D

    3

    45

    90

    0.0785

    8.9

    180

    130

    160

    80

    87

    7*11

    SOCL-0110-EISA-640D

    3

    55

    110

    0.064

    14.4

    230

    160

    220

    110

    85

    9*18

    SOCL-0150-EISA-467D

    3

    75

    150

    0.0467

    15.0

    230

    160

    220

    110

    85

    9*18

    SOCL-0180-EISA-390D

    3

    90

    180

    0.039

    19.2

    230

    175

    220

    110

    100

    9*18

    SOCL-0220-EISA-320D

    3

    110

    220

    0.032

    20.3

    230

    175

    220

    110

    100

    9*18

    SOCL-0260-EISA-270D

    D

    3

    132

    260

    0.027

    26.5

    260

    185

    265

    140

    110

    9*18

    SOCL-0320-EISA-220D

    3

    160

    320

    0.022

    27.7

    260

    185

    265

    140

    110

    9*18

    SOCL-0400-EISA-175D

    3

    200

    400

    0.0175

    33.1

    300

    205

    280

    170

    110

    11*18

    SOCL-0480-EISA-145D

    3

    250

    480

    0.0145

    45.0

    300

    230

    280

    170

    135

    11*18

    SOCL-0540-EISA-130D

    3

    280

    540

    0.013

    45.8

    300

    230

    280

    170

    135

    11*18

    SOCL-0600-EISA-117D

    3

    315

    600

    0.0117

    46.8

    300

    230

    280

    170

    135

    11*18

    SOCL-0800-EISA-875E

    2

    400

    800

    0.00875

    66.0

    360

    255

    375

    190

    135

    13*26

    SOCL-1000-EISA-700E

    2

    500

    1000

    0.007

    69.3

    360

    255

    375

    190

    135

    13*26

    SOCL-1100-EISA-635E

    E

    2

    560

    1100

    0.00635

    98.0

    430

    305

    410

    240

    175

    14*28

    SOCL-1200-EISA-585E

    2

    630

    1200

    0.00585

    100.0

    430

    305

    410

    240

    175

    14*28

    System voltage: 3-AC690V,50HZ, Insulation level: F

    Specifications and   models

    Figure  No.

    Carrier frequency(KHZ

    Power of frequency converter (kW)

    Rated current(A)

    Inductance   (mH)

    Weight   (KG)

    Dimensions(mm)

    W

    D

    H

    W0

    D0

    A*B

    SOCL-0020-EISC-640C

    B

    2

    15

    20

    0.64

    5.4

    150

    95

    160

    60

    67

    7*11

    SOCL-0030-EISC-425C

    2

    22

    30

    0.425

    8.7

    180

    130

    190

    80

    87

    7*11

    SOCL-0045-EISA-255C

    C

    2

    37

    45

    0.255

    12.7

    230

    160

    190

    110

    85

    9*18

    SOCL-0060-EISA-212C

    2

    45

    60

    0.212

    14.6

    230

    160

    220

    110

    85

    9*18

    SOCL-0090-EISA-141C

    2

    75

    90

    0.141

    15.4

    230

    160

    220

    110

    85

    9*18

    SOCL-0110-EISA-115C

    2

    90

    110

    0.115

    20.1

    230

    175

    220

    110

    100

    9*18

    SOCL-0150-EISA-850D

    2

    110

    150

    0.085

    20.8

    230

    175

    220

    110

    100

    9*18

    SOCL-0200-EISA-640D

    D

    2

    160

    200

    0.064

    28.7

    260

    185

    265

    140

    110

    9*18

    SOCL-0250-EISA-510D

    2

    200

    250

    0.051

    30.6

    260

    185

    265

    140

    110

    9*18

    SOCL-0300-EISA-425D

    2

    250

    300

    0.0425

    36.8

    300

    200

    280

    170

    110

    11*18

    SOCL-0400-EISA-320D

    1.5

    355

    400

    0.032

    48.9

    300

    225

    280

    170

    135

    11*18

    SOCL-0480-EISA-265D

    1.5

    450

    480

    0.0265

    68.8

    360

    250

    375

    190

    135

    13*26

    SOCL-0600-EISA-213D

    1.5

    560

    600

    0.0213

    71.1

    360

    250

    375

    190

    135

    13*26

    SOCL-0800-EISA-160D

    E

    1.5

    710

    800

    0.016

    100.5

    430

    290

    410

    240

    175

    14*28

    SOCL-1000-EISA-127D

    1.5

    900

    1000

    0.0127

    100.6

    430

    290

    410

    240

    175

    14*28

    SOCL-1100-EISA-115D

    1.5

    1000

    1100

    0.0115

    134.8

    430

    310

    520

    240

    190

    14*28

    SOCL-1400-EISA-900E

    1.5

    1200

    1400

    0.009

    144.5

    430

    310

    520

    240

    190

    14*28

    System voltage: 3-AC690V, 50HZ, double-quadrant explosion-proof series frequency converter, Insulation level: H; Ceiling of reactor temperature rise≤70K-80K

    Specifications and   models

    Figure  No.

    Carrier frequency(KHZ

    Power of frequency converter (kW)

    Rated current(A)

    Inductance   (mH)

    Weight   (KG)

    Dimensions(mm)

    W

    D

    H

    W0

    D0

    A*B

    FOCL-0090-EISC-141C

    C

    2

    75

    90

    0.141

    18.1

    230

    145

    220

    110

    85

    9*18

    FOCL-0110-EISC-115C

    2

    90

    110

    0.115

    21.5

    230

    160

    220

    110

    100

    9*18

    FOCL-0150-EISC-850D

    2

    110

    150

    0.085

    24.4

    230

    170

    220

    110

    100

    9*18

    FOCL-0200-EISC-640D

    D

    2

    160

    200

    0.064

    32.4

    260

    180

    265

    140

    110

    9*18

    FOCL-0250-EISC-510D

    2

    200

    250

    0.051

    37.9

    260

    180

    265

    140

    110

    9*18

    FOCL-0300-EISC-425D

    2

    250

    300

    0.0425

    45.4

    300

    185

    280

    170

    110

    11*18

    FOCL-0400-EISC-320D

    1.5

    355

    400

    0.032

    59.7

    300

    225

    280

    170

    135

    11*18

    FOCL-0480-EISC-265D

    1.5

    450

    480

    0.0265

    76.8

    360

    245

    375

    190

    135

    13*26

    FOCL-0600-EISC-213D

    1.5

    560

    600

    0.0213

    86.2

    360

    245

    375

    190

    135

    13*26

    FOCL-0800-EISC-160D

    E

    1.5

    710

    800

    0.016

    107.6

    430

    280

    410

    240

    175

    14*28

    FOCL-1000-EISC-127D

    1.5

    900

    1000

    0.0127

    118.7

    430

    280

    410

    240

    175

    14*28

    FOCL-1100-EISC-115D

    1.5

    1000

    1100

    0.0115

    149.2

    430

    300

    520

    240

    190

    14*28

    FOCL-1400-EISC-900E

    1.5

    1200

    1400

    0.009

    166.4

    430

    320

    520

    240

    190

    14*28

    System voltage: 3-AC1140V, 50HZ, double-quadrant explosion-proof series frequency converter, Insulation level: H; Ceiling of reactor temperature rise≤70K-80K

    Specifications and   models

    Figure  No.

    Carrier frequency(KHZ

    Power of frequency converter (kW)

    Rated current(A)

    Inductance   (mH)

    Weight   (KG)

    Dimensions(mm)

    W

    D

    H

    W0

    D0

    A*B

    FOCL-0110-EISC-190C

    D

    2

    160

    110

    0.19

    33.8

    260

    180

    265

    140

    110

    9*18

    FOCL-0150-EISC-140C

    2

    200

    150

    0.14

    40.1

    260

    180

    265

    140

    110

    9*18

    FOCL-0200-EISC-105C

    2

    280

    200

    0.105

    48.8

    300

    180

    280

    170

    110

    11*18

    FOCL-0250-EISC-840D

    1.5

    355

    250

    0.084

    63.2

    300

    205

    280

    170

    135

    11*18

    FOCL-0300-EISC-700D

    1.5

    450

    300

    0.07

    78.7

    360

    205

    375

    190

    135

    13*26

    FOCL-0350-EISC-600D

    1.5

    500

    350

    0.06

    85.0

    360

    215

    375

    190

    135

    13*26

    FOCL-0400-EISC-525D

    1.5

    630

    400

    0.0525

    85.3

    360

    245

    375

    190

    135

    13*26

    FOCL-0480-EISC-438D

    E

    1.5

    710

    480

    0.0438

    118.7

    430

    270

    410

    240

    175

    14*28

    FOCL-0600-EISC-350D

    1.5

    900

    600

    0.035

    124.4

    430

    270

    410

    240

    175

    14*28

    FOCL-0700-EISC-300D

    1.5

    1000

    700

    0.03

    156.5

    430

    280

    520

    240

    190

    14*28

    FOCL-0800-EISC-263D

    1.5

    1200

    800

    0.0263

    171.9

    430

    280

    520

    240

    190

    14*28

    Remarks:Copper DC reactor(type EISC) will be a little heavier, the remaining items are the same, A/B/C stand for three-phase input side;X/Y/Z stand for output side.



    Technical parameter of output reactor(UD=2%)

    System voltage: 3-AC400V,50HZ, Insulation level: F

    Specifications and   models

    Figure  No.

    Carrier frequency(KHZ

    Power of frequency converter (kW)

    Rated current(A)

    Inductance   (mH)

    Weight   (KG)

    Dimensions(mm)

    W

    D

    H

    W0

    D0

    A*B

    SOCL-0005-EISC-280B

    A

    5

    2.2

    5

    2.8

    3.0

    115

    73

    125

    50

    53

    7*11

    SOCL-0010-EISC-140B

    B

    5

    3.7

    10

    1.4

    6.0

    150

    95

    160

    60

    67

    7*11

    SOCL-0013-EISC-108B

    5

    5.5

    13

    1.08

    6.0

    150

    95

    160

    60

    67

    7*11

    SOCL-0016-EISC-875C

    5

    7.5

    16

    0.875

    6.0

    150

    95

    160

    60

    67

    7*11

    SOCL-0025-EISC-560C

    4

    11

    25

    0.56

    8.4

    180

    130

    190

    80

    87

    7*11

    SOCL-0030-EISC-467C

    4

    15

    30

    0.467

    8.7

    180

    130

    190

    80

    87

    7*11

    SOCL-0040-EISA-350C

    C

    4

    18.5

    40

    0.35

    12.4

    230

    160

    190

    110

    85

    9*18

    SOCL-0045-EISA-311C

    4

    22

    45

    0.311

    12.6

    230

    160

    190

    110

    85

    9*18

    SOCL-0060-EISA-234C

    3

    30

    60

    0.234

    14.3

    230

    160

    220

    110

    85

    9*18

    SOCL-0075-EISA-187C

    3

    37

    75

    0.187

    14.5

    230

    160

    220

    110

    85

    9*18

    SOCL-0090-EISA-155C

    3

    45

    90

    0.155

    14.9

    230

    160

    220

    110

    85

    9*18

    SOCL-0110-EISA-128C

    3

    55

    110

    0.128

    19.0

    230

    175

    220

    110

    100

    9*18

    SOCL-0150-EISA-934D

    3

    75

    150

    0.0934

    19.8

    230

    175

    220

    110

    100

    9*18

    SOCL-0180-EISA-780D

    D

    3

    90

    180

    0.078

    26.8

    260

    185

    265

    140

    110

    9*18

    SOCL-0220-EISA-640D

    3

    110

    220

    0.064

    27.8

    260

    185

    265

    140

    110

    9*18

    SOCL-0260-EISA-540D

    3

    132

    260

    0.054

    33.9

    300

    195

    280

    170

    110

    11*18

    SOCL-0320-EISA-438D

    3

    160

    320

    0.0438

    35.8

    300

    195

    280

    170

    110

    11*18

    SOCL-0400-EISA-350D

    3

    200

    400

    0.035

    47.5

    300

    225

    280

    170

    135

    11*18

    SOCL-0480-EISA-290D

    3

    250

    480

    0.029

    66.1

    360

    250

    375

    190

    135

    13*26

    SOCL-0540-EISA-260D

    3

    280

    540

    0.026

    67.9

    360

    250

    375

    190

    135

    13*26

    SOCL-0600-EISA-234D

    3

    315

    600

    0.0234

    69.3

    360

    250

    375

    190

    135

    13*26

    SOCL-0800-EISA-175D

    E

    2

    400

    800

    0.0175

    96.0

    430

    290

    410

    240

    175

    14*28

    SOCL-1000-EISA-140D

    2

    500

    1000

    0.014

    100.7

    430

    290

    410

    240

    175

    14*28

    SOCL-1100-EISA-127D

    2

    560

    1100

    0.0127

    134.8

    430

    305

    520

    240

    190

    14*28

    SOCL-1200-EISA-117D

    2

    630

    1200

    0.0117

    137.5

    430

    305

    520

    240

    190

    14*28

    System voltage: 3-AC690V,50HZ, Insulation level: F

    Specifications and   models

    Figure  No.

    Carrier frequency(KHZ

    Power of frequency converter (kW)

    Rated current(A)

    Inductance   (mH)

    Weight   (KG)

    Dimensions(mm)

    W

    D

    H

    W0

    D0

    A*B

    SOCL-0020-EISC-128B

    B

    2

    15

    20

    1.28

    8.3

    180

    130

    190

    80

    87

    7*11

    SOCL-0030-EISC-850C

    2

    22

    30

    0.85

    9.0

    180

    130

    190

    80

    87

    7*11

    SOCL-0045-EISA-565C

    C

    2

    37

    45

    0.565

    18.7

    230

    175

    220

    110

    100

    9*18

    SOCL-0060-EISA-425C

    2

    45

    60

    0.425

    19.0

    230

    175

    220

    110

    100

    9*18

    SOCL-0090-EISA-282C

    D

    2

    75

    90

    0.282

    26.7

    260

    185

    265

    140

    110

    9*18

    SOCL-0110-EISA-230C

    2

    90

    110

    0.23

    27.6

    260

    185

    265

    140

    110

    9*18

    SOCL-0150-EISA-170C

    2

    110

    150

    0.17

    33.7

    300

    190

    280

    170

    110

    11*18

    SOCL-0200-EISA-128C

    2

    160

    200

    0.128

    46.4

    300

    215

    280

    170

    135

    11*18

    SOCL-0250-EISA-102C

    2

    200

    250

    0.102

    66.0

    360

    215

    375

    190

    135

    13*26

    SOCL-0300-EISA-850D

    2

    250

    300

    0.085

    67.7

    360

    215

    375

    190

    135

    13*26

    SOCL-0400-EISA-640D

    E

    1.5

    355

    400

    0.064

    94.9

    430

    270

    410

    240

    175

    14*28

    SOCL-0480-EISA-530D

    1.5

    450

    480

    0.053

    97.8

    430

    270

    410

    240

    175

    14*28

    SOCL-0600-EISA-425D

    1.5

    560

    600

    0.0425

    103.3

    430

    270

    410

    240

    175

    14*28

    SOCL-0800-EISA-320D

    1.5

    710

    800

    0.032

    135.2

    430

    285

    520

    240

    190

    14*28

    SOCL-1000-EISA-254D

    F

    1.5

    900

    1000

    0.0254

    159.2

    480

    315

    540

    200

    190

    14*28

    SOCL-1100-EISA-230D

    1.5

    1000

    1100

    0.023

    211.3

    480

    340

    660

    200

    210

    14*28

    SOCL-1400-EISA-180D

    1.5

    1200

    1400

    0.018

    220.7

    480

    370

    660

    200

    210

    14*28

    System voltage: 3-AC690V, 50HZ, double-quadrant explosion-proof series frequency converter, Insulation level: H; Ceiling of reactor temperature rise≤70K-80K

    Specifications and   models

    Figure  No.

    Carrier frequency(KHZ

    Power of frequency converter (kW)

    Rated current(A)

    Inductance   (mH)

    Weight   (KG)

    Dimensions(mm)

    W

    D

    H

    W0

    D0

    A*B

    FOCL-0090-EISC-282C

    D

    2

    75

    90

    0.282

    29.1

    260

    170

    265

    140

    110

    9*18

    FOCL-0110-EISC-230C

    2

    90

    110

    0.23

    31.7

    260

    170

    265

    140

    110

    9*18

    FOCL-0150-EISC-170C

    2

    110

    150

    0.17

    38.2

    300

    180

    280

    170

    110

    11*18

    FOCL-0200-EISC-128C

    2

    160

    200

    0.128

    53.6

    300

    195

    280

    170

    135

    11*18

    FOCL-0250-EISC-102C

    2

    200

    250

    0.102

    71.5

    360

    210

    375

    190

    135

    13*26

    FOCL-0300-EISC-850D

    2

    250

    300

    0.085

    74.2

    360

    215

    375

    190

    135

    13*26

    FOCL-0400-EISC-640D

    E

    1.5

    355

    400

    0.064

    102.8

    430

    270

    410

    240

    175

    14*28

    FOCL-0480-EISC-530D

    1.5

    450

    480

    0.053

    109.8

    430

    270

    410

    240

    175

    14*28

    FOCL-0600-EISC-425D

    1.5

    560

    600

    0.0425

    124.7

    430

    290

    410

    240

    195

    14*28

    FOCL-0800-EISC-320D

    1.5

    710

    800

    0.032

    154.5

    430

    300

    510

    240

    195

    14*28

    FOCL-1000-EISC-254D

    F

    1.5

    900

    1000

    0.0254

    183.3

    480

    300

    540

    200

    190

    14*28

    FOCL-1100-EISC-230D

    1.5

    1000

    1100

    0.023

    232.0

    480

    340

    660

    200

    210

    14*28

    FOCL-1400-EISC-180D

    1.5

    1200

    1400

    0.018

    255.0

    480

    360

    660

    200

    210

    14*28

    System voltage: 3-AC1140V, 50HZ, double-quadrant explosion-proof series frequency converter, Insulation level: H; Ceiling of reactor temperature rise≤70K-80K

    Specifications and   models

    Figure  No.

    Carrier frequency(KHZ

    Power of frequency converter (kW)

    Rated current(A)

    Inductance   (mH)

    Weight   (KG)

    Dimensions(mm)

    W

    D

    H

    W0

    D0

    A*B

    FOCL-0110-EISC-380C

    D

    2

    160

    110

    0.38

    52.0

    300

    195

    280

    170

    135

    11*18

    FOCL-0150-EISC-280C

    2

    200

    150

    0.28

    71.3

    360

    205

    375

    190

    135

    13*26

    FOCL-0200-EISC-210C

    E

    2

    280

    200

    0.21

    97.6

    430

    230

    410

    240

    165

    14*28

    FOCL-0250-EISC-168C

    1.5

    355

    250

    0.168

    105.4

    430

    240

    410

    240

    175

    14*28

    FOCL-0300-EISC-140C

    1.5

    450

    300

    0.14

    107.4

    430

    245

    410

    240

    175

    14*28

    FOCL-0350-EISC-120C

    1.5

    500

    350

    0.12

    115.0

    430

    265

    410

    240

    195

    14*28

    FOCL-0400-EISC-105C

    1.5

    630

    400

    0.105

    147.4

    430

    295

    510

    240

    195

    14*28

    FOCL-0480-EISC-875D

    F

    1.5

    710

    480

    0.0875

    167.5

    480

    295

    540

    200

    190

    14*28

    FOCL-0600-EISC-700D

    1.5

    900

    600

    0.07

    187.3

    480

    295

    540

    200

    190

    14*28

    FOCL-0700-EISC-600D

    1.5

    1000

    700

    0.06

    234.1

    480

    320

    660

    200

    210

    14*28

    FOCL-0800-EISC-525D

    1.5

    1200

    800

    0.0525

    246.4

    480

    320

    660

    200

    210

    14*28


    Remarks:Copper  reactor(type EISC) will be a little heavier, the remaining items are the same, A/B/C stand for three-phase input side;X/Y/Z stand for output side.

    • Previous:没有了!
    • Next:没有了!

    Related Products