DC Balanced Reactor
    Variable Frequency Drive
    DC Flat Wave Reactor
    Input Reactor
    Output Reactor
    Energy Feedback Reactor
    Reactor of PMSM
    Rotor Inverter BOOST Reactor
    Dv/dt Filter
    Sine Wave Filter
    Passive Harmonic Filter
    LCL Filter
    EMC Filter
    Power Quality
    SVG Reactor
    APF Reactor
    Three Phase Series Detuning Reactor
    Three Phase Series Tuned Reactor
    Single-phase series detuning reactor
    New Energy
    Wind Power Filter Reactor
    Photovoltaic Filter Reactor
    Photovoltaic Isolation Transformer
    Transformer
    Rectifier Transformer
    Power Frequency Transformer
    Energy Consumption Braking
    Braking Unit
    Wirewound Resistor
    Aluminum-enclosure Resistor
    Braking Resistance Box
    Braking Resistance Cabinet
    Electric Vehicle
    BOOST Reactor For EV
    PFC Reactor for Charger
    High Frequency Reactor
    High Frequency Transformer

    Recommend

    Sine Wave Filter

    Time:2024-01-19     Visits:7


    Circuitry application: At the output side of frequency converter in a synchronous motor frequency conversion transmission system, inhibits and absorb the higher harmonic current caused by the switching frequency ripple current, reduces the dv/dt instantaneous voltage caused by traveling wave reflection in long cable transmission, Correct  the waveform to approximate the sine wave, significantly extend the length of output cable, so as to reduce the eddy-current losses and the noise of the electric motor, and to protect the insulation of the motor. 

    Test effect:


    Performance features: 


    Rated voltage

    3-AC400V /690V,50HZ   

    Insulation level

    F

    Noise

    ≤70 dB

    Electric resistance

    AC3000V/AC4200V   50Hz  5s  leakage current≤5m A

    Working temperature

    -25℃~55℃

    Operative norm

    GB10229-88 reactor、IEC289:1987 reactor、JB9644-1999 reactor for transmission semiconductor    



    Dimensions and technical parameter:




    Technical parameter of Sinusoidal Filter(UD=8%-12.5%)



    Rated voltage of system:3-AC400V,  THDI≤5%, Mix length of output cable 1000m

    Specifications and models

    Figure  No.

    Carrier frequency(KHZ)

    Power of frequency converter kW

    Rated currentA

    Cut-off frequency(KHZ

    Dimensions(mm)

    W

    D

    H

    W0

    D0

    A*B

    SLB-0005-EISA

    A

    5

    2.2

    5

    5.1

    150

    105

    160

    60

    67

    7*11

    SLB-0010-EISA

    5

    3.7

    10

    6.1

    180

    120

    190

    80

    67

    7*11

    SLB-0013-EISA

    5

    5.5

    13

    8.8

    180

    140

    190

    80

    87

    7*11

    SLB-0016-EISA

    5

    7.5

    16

    9

    180

    140

    190

    80

    87

    7*11

    SLB-0025-EISA

    4

    11

    25

    13.5

    230

    160

    220

    110

    85

    9*18

    SLB-0030-EISA

    4

    15

    30

    13.8

    230

    160

    220

    110

    85

    9*18

    SLB-0040-EISA

    4

    18.5

    40

    16.5

    230

    165

    265

    110

    85

    9*18

    SLB-0045-EISA

    4

    22

    45

    19.3

    230

    175

    265

    110

    95

    9*18

    SLB-0060-EISA

    B

    3

    30

    60

    27.7

    260

    205

    285

    140

    110

    9*18

    SLB-0075-EISA

    3

    37

    75

    33.8

    300

    230

    285

    170

    110

    11*18

    SLB-0090-EISA

    3

    45

    90

    35.7

    300

    230

    285

    170

    110

    11*18

    SLB-0110-EISA

    C

    3

    55

    110

    58.5

    360

    250

    375

    190

    125

    13*26

    SLB-0150-EISA

    3

    75

    150

    67.7

    360

    260

    375

    190

    135

    13*26

    SLB-0180-EISA

    3

    90

    180

    85.7

    430

    305

    410

    240

    165

    14*28

    SLB-0220-EISA

    3

    110

    220

    89.4

    430

    305

    410

    240

    165

    14*28

    SLB-0260-EISA

    3

    132

    260

    115.7

    430

    335

    410

    240

    195

    14*28

    SLB-0320-EISA

    3

    160

    320

    128.6

    430

    345

    410

    240

    205

    14*28

    SLB-0400-EISA

    3

    200

    400

    161.9

    430

    355

    510

    240

    215

    14*28

    SLB-0480-EISA

    3

    250

    480

    168.8

    430

    355

    510

    240

    215

    14*28

    SLB-0600-EISA

    D

    3

    315

    600

    194.3

    480

    380

    540

    200

    210

    14*28

    SLB-0800-EISA

    2

    400

    800

    266

    480

    460

    660

    200

    230

    14*28

    SLB-1000-EISA

    2

    500

    1000

    319.6

    540

    470

    690

    220

    230

    14*28

    SLB-1200-EISA

    2

    630

    1200

    392

    600

    520

    710

    240

    240

    14*28